An increase in temperature weakens the oxygen-nitrogen separation ability.
The core advantage of carbon molecular sieves is their adsorption selectivity for O₂ and N₂ (that is, the ability to adsorb O₂ while repelling N₂), and this selectivity significantly weakens with an increase in temperature:
- The selective adsorption mechanism is disrupted.
At room temperature, the adsorption capacity of CMS for O₂ is approximately 5-10 times that of N₂ (because O₂ molecules are more polar and have a slightly smaller dynamic diameter, making them more easily captured by micropores). When the temperature rises, the absolute value of the adsorption enthalpy of O₂ (-40~-50 kJ/mol) is greater than that of N₂ (-20~-30 kJ/mol), resulting in a more pronounced desorption trend for O₂ and an increase in the "false adsorption" probability of N₂, with the selectivity dropping from 10:1 to 3:1 or even lower.
- The purity of nitrogen has directly decreased.
The reduction in selectivity has led to more O₂ not being adsorbed and being mixed into the product nitrogen, while some N₂ that has been adsorbed is released along with the desorption exhaust gas. For example:
When the intake air temperature rises from 25℃ to 45℃, the nitrogen purity may drop from 99.99% to below 99.5% (without adjusting the process parameters);
To maintain the target purity, the adsorption time needs to be extended or the production volume reduced, resulting in a decrease in equipment efficiency.