The influence of compressed gas temperature on the adsorption capacity of carbon molecular sieves
An increase in temperature leads to a significant decrease in adsorption capacity.
- The adsorption of oxygen by carbon molecular sieves is a physical adsorption (due to van der Waals forces), and its adsorption
capacity shows a clear negative correlation with temperature. Specifically, it is manifested as:
The molecular motion intensifies, and the adsorption equilibrium shifts towards desorption.
As the temperature rises, the thermal motion energy of gas molecules increases, and O₂molecules are more likely to overcome the van der Waals force binding within the CMS micropores, resulting in a decrease in the adsorption equilibrium constant. Experimental data show:
At room temperature (25℃), the adsorption capacity of high-quality CMS for O₂is approximately 20-25 mL/g (in standard conditions);
When the temperature rises to 40℃, the adsorption capacity can decrease to 15-18 mL/g, a reduction of 20%-30%;
If the temperature exceeds 50℃, the adsorption capacity may fall below 10 mL/g, which cannot meet the industrial nitrogen production requirements (typically requiring nitrogen purity ≥ 99.5%).

- Change in diffusion resistance within micropores
The adsorption of CMS depends on the diffusion of O₂molecules into the micropores (with pore diameters of 0.3-0.5 nm). At high temperatures, the gas viscosity decreases and the flow rate increases, and some O₂molecules may not be adsorbed due to insufficient diffusion time, further reducing the effective adsorption capacity.